Conversion Kit
6
4)
To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables below.
PTS605U - Natural gas PTS605U - LP
Qt Injector Qr Qt Injector Qr by-pass
BTU Ø mm BTU BTU Ø mm BTU mm
Left Central 14000 1.60 4400 Left Central 14000 1.10 4400 0.65
Central
Front
3400 0.80 1500
Central
Front
3400 0.54 1500 0.33
Central
Rear
6000 1.05 1800
Central
Rear
6000 0.73 1800 0.37
Right
Central
9000 1.26 3400
Right
Central
9000 0.89 3400 0.50
PTS727U - Natural gas PTS727U - LP
Qt Injector Qr Qt Injector Qr by-pass
BTU Ø mm BTU BTU Ø mm BTU mm
Left Central
Inner
3000 0.73 1500
Left Central
Inner
3000 0.50 1500 0.33
Left Central
Outer
13000 1.55 4400
Left Central
Outer
13000 1.05 4400 0.65
Central
Front
3400 0.80 1500
Central
Front
3400 0.54 1500 0.33
Central
Rear
6000 1.05 1800
Central
Rear
6000 0.73 1800 0.37
Right Front 3400 0.80 1500 Right Front 3400 0.54 1500 0.33
Right Rear 9000 1.26 3400 Right Rear 9000 0.89 3400 0.50
NOTE: Save the nozzles removed from the appliance for future use.