Smeg PTS605NU3 Manuel d'instructions Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
Conversion Kit
7
5)
Remove the screw A and push the support B fully down. Remove the nozzle C with a wrench and insert
the suitable nozzle following the instructions in the tables referring to the type of gas to be used. The
nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original
position, so that the nozzle C is perfectly covered.
Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the
primary air flow” is obtained and secure it with screw A. When theadjustments are complete, restore the
seals with wax or a similar material.
6)
Referring to distance “X” in mm.
PTS605U – Natural gas PTS605U – LP
Air Shutter Air Shutter
Left Central
2
/
8
” - 7.0 mm
Left Central
1
/
2
” - 12.0 mm
Central Front
2
/
8
” - 7.0 mm
Central Front
2
/
8
” - 7.0 mm
Central Rear
2
/
8
” - 7.0 mm
Central Rear
2
/
8
” - 7.0 mm
Right Central
3
/
16
” - 4.0 mm
Right Central
3
/
8
” - 10.0 mm
PTS727U – Natural gas PTS727U– LP
Air Shutter Air Shutter
Left
Central
Inner
3
/
8
” - 10.0 mm
Left
Central
Inner
2
/
8
” - 7.0 mm
Outer
3
/
8
” - 10.0 mm
Outer
1
/
2
” - 12.0 mm
Central Front
2
/
8
” - 7.0 mm
Central Front
2
/
8
” - 7.0 mm
Central Rear
3
/
8
” - 7.0 mm
Central Rear
2
/
8
” - 7.0 mm
Right Front
2
/
8
” - 7.0 mm
Right Front
2
/
8
” - 7.0 mm
Right Rear
3
/
16
” - 4.0 mm
Right Rear
3
/
8
” - 10.0 mm
7)
After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”.
Caution: refit all flame caps in the same points from which they were removed. In fact, the flame cap
positions cannot be changed. After refitting them, ensure that they are perfectly positioned and that there
is no clearance between the cooktop and the flame caps.
WARNING
FIRE HAZARD
- Use a soapy solution to check for proper tightness.
- Never test for gas leaks with a match or other flames.
- Failure to follow this instruction can result in death or fire.