Instructions for the installer
9
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 30 350 73 71
Semi rapid 1.75 65 33 450 127 125
Rapid 2.3 75 45 800 167 164
Rapid * 2.5 79 45 800 182 179
Triple crown 3.5 94 65 1500 254 250
Oven 3.2 87 48 850 233 229
Maxi oven 4.6 106 59 1200 378 371
Grill 3.7 95 // // 268 264
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350
Semi rapid 1.75 97 450
Rapid 2.3 103 800
Rapid * 2.5 108 800
Triple crown 3.5 140 1500
Oven 3.2 130 850
Maxi oven 4.6 155 1200
Grill 3.7 145 //
*
Nozzle supplied only on some models
3.3 Arrangement of the burners on the hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Triple crown
Commentaires sur ces manuels