Instructions for the installer
20
14.2 Burner and nozzle characteristics table
Burner
Rated heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 30 350 72 71
Semi rapid 1.75 65 33 450 127 125
Rapid 3 85 45 800 217 214
Triple crown 3.2 91 65 1500 232 228
Burner
Rated heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350
Semi rapid 1.75 97 450
Rapid 3 115 800
Triple crown 3.5 140 1500
14.3 Arrangement of the burners on the hob
BURNERS
1 Auxiliary
2 Semi rapid
3Rapid
4 Triple crown
ø min e max (in cm.)
12 - 14
16 - 24
18 - 26
18 - 26
Vue de la page 17