Smeg Arco Isola Plus KSEIV96X Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
21GB
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
The filter is not washable and cannot be
regenerated. It must be replaced when led S2
flashes or at least every 4 months. The alarm
signal will only light up when the extractor
motor is switched on.
Alarm signal reset
Switch off the lights and extractor motor.
Press button V3 for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
Remove the metal grease filters
Remove the saturated activated carbon filter by
releasing the fixing hooks
Fit the new filter by hooking it into its seating
Replace the metal grease filters.
Alarm signal activation
On the recirulcation version extractor hood, the
filter saturation alarm is activated during
installation or at a later date.
Switch off the lights and extractor motor.
Press button V3 for at least 10 seconds, until
the leds start to flash:
2 flashes of the activated carbon odour filter
saturation alarm led = filter ACTIVATED
1 flash of the activated carbon odour filter
saturation alarm led = filter DEACTIVATED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the ring nut.
Extract the lamp from the lamp holder by pulling
gently.
Replace with another of the same type, making
sure that the two pins are properly inserted in
the lamp holder socket holes.
Replace the ring nut and fix it in place using the
two screws removed as above.
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12

Commentaires sur ces manuels

Pas de commentaire