Smeg KCVR9NE Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
EN
KCVR9NE
RESET FILTRI:
Resets the filter saturation alarm if pressed for 2s when all the loads
(motor+lights) are off.
• If there is a metal Filter sat. alarm, FF appears on the display, after 100 h
of
operation.
• If there is a CA filter alarm, EF appears on the display after 200h of
operation.
REDUCE LIGHT INTENSITY
LIGHTS ON/OFF
Turns the hood lights on and off at maximum intensity. The increase/reduce
buttons adjust the lights’ intensity by 4 steps, excluding max. intensity.
INCREASE LIGHT INTENSITY
Keypad lock:
Locks keyboard functions (for example, when cleaning the glass surface)
when all the loads are off and no alarm is on. To enable/disable this
function, press the BOOST-SPEED button for about 5s until the two central
segments of every digit on the display light up.
Vue de la page 6
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire