Smeg P23LINP Guide de dépannage

Naviguer en ligne ou télécharger Guide de dépannage pour Foyers Smeg P23LINP. Smeg P23LINP fireplace Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTALLATION & USER INSTRUCTIONS
All instructions must be handed to the user for
safekeeping.
M
ODELS COVERED BY THESE INSTRUCTIONS
P23 LINEAR - P23LIN
P23 CLASSIC - P23CL
L23 LINEAR - L23LIN
L23 CLASSIC - L23CL
L30 FAB - L30FAB
SMEG S.p.A. 42016
Guastalla (RE)
I
TALY
WALL MOUNTED HIGH EFFICIENCY GAS FIRE
P
23 Linear
P
23 Classic
L23 Classic
Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Smeg S.p.A. You are not permitted to
copy or adapt any of the content without the prior written
permission of Smeg S.p.A.
This product is tested and approved to EN14829 : 2007.
L23 Linear
L30 Fab
© 2008 Smeg S.p.A.
GB IE
GB-IE-1
Smeg EU-wide instal instruc-v7-English.qxp:Smeg EU-wide installation instructions DRAFT A-12-12-07.qxd 17/7/08 12:06 Page 1
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - 2008 Smeg S.p.A

INSTALLATION & USER INSTRUCTIONSAll instructions must be handed to the user forsafekeeping.MODELS COVERED BY THESE INSTRUCTIONSP23 LINEAR - P23LIN

Page 2

It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures. The expect-ed life of the catalys

Page 3 - 3.1 ROOM SIZING

Fire sparks but pilot does not light No gas to fire, check isolators are open.Pipe work blockage, clean out.Air not fully purged, re purge supply or w

Page 4 - 4.1 VENTILATION

• The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codesand/or Regulations, Buildin

Page 5 - 7.0 FIXING THE APPLIANCE

Clearances to combustible materialsCombustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Gener

Page 6 - 8.0 TESTING AND COMMISSIONING

Classic models : The control knob is located on thelower right hand side of the outer case. It is marked asshown in figure 2;Linear models : The contr

Page 7 - 8.2 SETTING PRESSURE

The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot.The frequency of ser

Page 8 - 10.0 SERVICING

• This appliance is a high efficiency, flueless catalytic flame effect gas fire. It provides radiant and convected warmth both effi-ciently and safely

Page 9 - 10.2 PILOT ASSEMBLY

DestinationCountryCatInlet Pressure(mbar)Max Energy Input(kW)Min Energy Input(kW)High BurnerPressure(±1.5 mbar)Low BurnerPressure(±0.75 mbar)G20 G25Gr

Page 10 - 10.3 CATALYSTS

This appliance may be installed in any room in the home except bathrooms. If the appli-ance is to be fitted in a bedroom then an electronic carbon mon

Page 11 - 11.0 TROUBLESHOOTING GUIDE

Remove the outer packaging, remove any instructions or fixing kits. Read ALL these instructions before continuing to unpack orinstall this appliance.

Page 12 - 1.0 IMPORTANT NOTES

If the appliance is to be mounted on a dry lined wall ora timber framed construction wall then efforts shouldbe made to fix in at least two positions

Page 13 - CONTINUED)

Classic models : The control knob is located on thelower right hand side of the outer case. It is marked asshown in figure 7;Linear models : The contr

Page 14 - 6.0 CLEANING

Please note that the Linear and Classic models aresupplied with a tinted glass facia assembly, which dif-fer in appearance when viewed from the front,

Page 15 - 8.0 LIST OF REPLACEMENT PARTS

All models : Firstly, remove the decorativeframe/glass facia assembly as described in section8.3. Remove the inner glass panel, and disconnectthe gas

Commentaires sur ces manuels