The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes
and/or Regulations, Building Regulations and the manufacturer's instructions.Failure to comply with the above could lead to
prosecution and invalidate the appliance warranty. In the event of gas leakage from the appliance, the gas supply must be turned
off at the nearest isolating valve. This appliance is only suitable for the gas type for which it is supplied.
Keep a note of the installer's name and address, the original purchase receipt and the date of installation. Failure to produce
this information may invalidate the warranty. The appliance should be serviced regularly to ensure continued safe operation.
See the servicing section for further reference.
The guard (glass front) is to prevent risk of fire or injury from burns and no part of
it should be permanently removed. It Does Not Give Full Protection For Young
Children Or The Infirm. Parts of this appliance become naturally hot during use.
It is recommended that a suitable fireguard is used, especially where young children,
pets, the elderly or infirm are concerned. The manufacturer of this appliance consid-
ers all surfaces as working surfaces with the exception of the control knob and con-
trol panel. Combustible items, such as flooring and furniture and soft wall coverings
(such as blown vinyl or embossed paper), low temperature surrounds etc may dis-
colour if fitted too close to the fire. See relevant section for further details on clear-
ances to combustibles. No combustible materials or flooring should protrude onto
the hearth (if fitted).
This appliance incorporates a combustion monitoring system (ODS).
DO NOT burn any foreign material on this fire. Under no circumstances shall the
appliance be used if the glass front door or panel has been removed, damaged or is
open. On no account should the appliance inlet or outlet openings be blocked or
obstructed in any way (see figure 1). DO NOT place objects on top of the appliance.
WARNING: Due to the nature of this product the area around the top of the appli-
ance (i.e. the grille) gets very hot. Care should be taken when operating the appliance.
The integral catalysts should be checked by the installer upon servicing to ensure there are no defects or obstructions that
may prevent the satisfactory flow of combustion products. The expected life of the catalyst is in excess of 11,000 hours (10
years of normal use). After this time the catalyst should be replaced.
U S E R I N S T R U C T I O N S
2.0 CLEARANCES TO COMBUSTIBLES
Note : L30FAB shown from rear as example,
however the air inlet and outlet openings are in
the same relative positions on all models.
Figure 1
Outlet openings :
DO NOT BLOCK
Inlet openings :
DO NOT BLOCK
© 2008 Smeg S.p.A.
GB IE
Section Content Page No
1.0 Important Notes 1
2.0 Clearances to Combustibles 1
3
.0 Ventilation & Room Size 2
4.0 Operating Instructions 3
5
.0 Combustion Monitoring System 3
6.0 Cleaning 3
7.0 Servicing 4
8.0 List of Replacement Parts 4
9
.0 Installation Details 4
10.0 Service History 4
11.0 Appliance Dimensions
Inside rear cover of booklet
Clearances to non-combustibles
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made materials impervious
to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
Clearances to the sides of the appliance are 100mm (4”). Clearance to the front of the appliance is 500mm (20”).
The back of the appliance may be installed directly onto a non-combustible wall, providing the area behind the appliance is flat
and does not interfere with the various vent holes in the back panel of the appliance.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm (16”) from the
top of the appliance glass panel and the wall above the appliance is non combustible.
The appliance must not be positioned vertically within 60mm (2.4”) of a solid floor (i.e. wood or stone) or hearth. This dimen-
sion is measured vertically to the bottom of the appliance firebox.
1.0 IMPORTANT NOTES
GB-IE-1