This appliance may be installed in any room in the home except bathrooms. If the appli-
ance is to be fitted in a bedroom then an electronic carbon monoxide detector com-
plying with the current edition of BSEN 50291 must be installed in the same room as
the appliance. For maximum safety it is recommended that such device is continuously
(mains) powered and arranged in such a way that the gas supply to the appliance is
isolated in the event of an alarm. The selection and installation of such device shall be
in accordance with the current edition of BSEN 50292, and the user must be briefed
regarding the use and maintenance of such a device.
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gentle draughts experienced
within the home. It is not recommended, however that the appliance be installed in areas where it is likely to be directly exposed to
persistent strong draughts, that may be generated by outside doors, windows, air vents, air conditioning units, extractor fans, ceiling fans
etc. See section 4.1 for more information on ventilation.
Clearances to non-combustible materials
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made materials impervi-
ous to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
Clearances to the sides of the appliance are 100mm (4”). Clearance to the front of the appliance is 500mm (20”).
The back of the appliance may be installed directly onto a non-combustible wall, providing the area behind the appliance is flat
and does not interfere with the various vent holes in the back panel of the appliance.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm (16”) from
the top of the appliance glass panel and the wall above the appliance is non combustible. The appliance must not be positioned
vertically within 60mm (2.4”) of a solid floor (i.e. wood or stone) or hearth. This dimension is measured vertically to the bottom
of the appliance firebox.
Clearances to combustible materials
Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any mate-
rial, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible mate-
rial or surface. Clearance to the sides of the appliance are 100mm (4”) but curtains, drapes and other fabrics are not permitted
within a distance of 500mm (20”) of the appliance sides. No such materials are permitted directly above the appliance regardless
of distance.
The minimum clearance to the ceiling above the appliance is 800mm (31.5”) measured from the top of the appliance glass panel.
Combustible materials should not be positioned directly in front of the appliance within a distance of one metre.
Under no circumstances should any electrical equipment e.g. plasma/LCD screen TV sets etc. be positioned on the wall above
the appliance. The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire sur-
round. No combustible shelves should be positioned on the wall above the appliance. It should be established that any mirrors
or picture frames etc. to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate
heat and moisture before proceeding with their installation.
The back of the appliance may be installed directly onto a combustible wall, providing it is relatively flat and does not interfere
with the various vent holes in the back panel of the appliance. The wall must be structurally sound and constructed from a mate-
rial capable of withstanding moderate heat. Brick, concrete, finished plaster, most types of conventional wall paper and dry-lined
plasterboard are examples of suitable materials. Materials such as flock, blown vinyl and embossed paper which are sensitive to
even small amounts of heat should be avoided as scorching and or discolouration may occur over time.
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the
wall to carry the weight of the appliance must be confirmed. It is important in these circumstances that any vapour control bar-
rier is not damaged, and that any structural members of the house frame are not damaged - refer to section 7.0.
The appliance must not be positioned vertically within 100 mm (4”) of a carpeted floor, rugs or fabric materials of any kind. This
dimension is measured vertically to the bottom of the appliance firebox.
GB only : A minimum of 100 cm
2
purpose provided ventilation MUST be provided for this appliance. This may be achieved
either with one vent 100 cm
2
at a high or low position in the room, or split ventilation i.e. 50cm
2
be installed at high level and
50cm
2
be installed at low level within the room. An openable window or equivalent is also required. To reduce the possibility
of draughts, road noise or insects entering the room via the air vent, we recommend the use an air vent of the type that feature
internal baffles.
IE only : Refer to the current edition of IS813.
The requirements of any other gas, oil or solid fuel appliances operating in the same room or space must be taken into consid-
eration when assessing ventilation.
Any ventilation fitted must comply with any relevant local codes for the installation of ventilation.
Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may adversely effect performance
of the ODS system. The appliance shall not be installed within 1 metre of any existing air vent, and any new air vent shall not be
installed within 1 metre of the appliance.
Note : With the appliance installed in the minimum size room and with the ventilation specified, the concentration of NO2 in
the room is less than 300ppb.
4.0 SITE REQUIREMENTS
This appliance is designed to be
wall-hung. Do not recess any part
of the appliance into the wall.
W
ARNING
©
2008 Smeg S.p.A.
GB IE
4.1 VENTILATION
GB-IE-4
!
Smeg EU-wide instal instruc-v7-English.qxp:Smeg EU-wide installation instructions DRAFT A-12-12-07.qxd 17/7/08 12:07 Page 4