Classic models : The control knob is located on the
lower right hand side of the outer case. It is marked as
s
hown in figure 7;
L
inear models : The control knob is located on the
lower right hand side of the outer case. It is marked as
shown in figure 8;
F
ab models : The control knob is located on the
lower right hand side of the outer case. It is of a spher-
ical design and is marked as shown in figure 9;
The pilot is visible behind the left hand side of the
b
urner. Push in and turn the control knob to the SPARK position, and hold there for a few
seconds. Continue turning anti-clockwise through the spark click to the PILOT light posi-
tion, ensuring the pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob pressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If the pilot is extinguished during use,
wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-
clockwise to the high position. The main burner should light after a few seconds. To
decrease the setting to low, turn the control knob clockwise to the LOW setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob
in, and return to the pilot position and release. To turn the fire off, keep the knob pressed
in, return to the OFF position and release.
All models : The pressure test point is located on the left
hand side of the appliance, on the main burner pipe, next to the
brass restrictor/connector. Remove the burner cover plate to
access, by removal of the four retaining screws as shown in fig-
ure 10. Release the setting pressure test point screw (shown in
figure 11), and attach a pressure gauge. Light the fire on the
HIGH setting.
To commission the appliance, the burner pressure must be in
accordance with the figures stated in section 2.0 of these
instructions. The fire is factory set to achieve these pressures
and any significant variation could indicate a supply problem. If
the pressure is too high, the gas supply meter may be set incor-
rectly. This should be checked with the fire running and if nec-
essary reset by the gas supplier.
If the burner pressure is too low, then check the inlet pressure
with the appliance running. If this is less than the inlet pressure
stated in section 2.0 of these instructions it will need to be reset
by the gas supplier. If the setting pressure is too low, but the
meter pressure is acceptable, then a problem in the supply
pipework is to be suspected.
Upon satisfactory checking of the burner pressure, turn the fire
off, disconnect the pressure gauge and refit the test point
screw. Light the fire and check for gas soundness. Re-fit the
burner cover plate, and replace the four retaining screws.
In the event that the burner pressure is not in accordance with the figures stated in the data section of these instructions, the
appliance must not be commissioned, and the manufacturer should be contacted for guidance.
8.1 OPERATING THE APPLIANCE
OFF position
SPARK position
LOW position
HIGH position
Figure 8
Figure 9
8.2 SETTING PRESSURE
L23 model shown as example
Fab model shown as example
Figure 10
Figure 11
Figure 7
© 2008 Smeg S.p.A.
GB IE
GB-IE-7
Smeg EU-wide instal instruc-v7-English.qxp:Smeg EU-wide installation instructions DRAFT A-12-12-07.qxd 17/7/08 12:07 Page 7
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Commentaires sur ces manuels

Pas de commentaire