Summary 1 INSTRUCTIONS FOR SAFE AND PROPER USE_______________ 20 2 POSITIONING OF THE HOB_______________________________ 22 3 ADJUSTMENT TO DIFFE
Instructions for the installer 28 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug the applia
Instructions for the installer 3.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) LPG – G30/G31 30/37 mbar N
Instructions for the installer 30 4 FINAL OPERATIONS After carrying out the above adjustments, remount in reverse order to the instructions given
Instructions for the user 5 USING THE HOB 5.1 Ignition of the burners Before turning on the burners, make sure that the flame-spreader crowns
Instructions for the user 32 5.2 Practical advice for using the burners For better use of the burners and lower gas consumption, use covered cooki
Instructions for the user 6 CLEANING AND MAINTENANCE Before any intervention, disconnect the appliance from the mains. Never use a steam jet
Instructions for the user 34 In models with central pan stand, fit this piece, taking care that its centre isperfectly aligned with the centre
Introduction 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AN
Introduction THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER THE SAFETY C
Instructions for the installer 22 2 POSITIONING OF THE HOB The following operation requires building and/or carpentry work so must be carried out
Instructions for the installer 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figu
Instructions for the installer 24 Important: Other types of installation will only be possible under themanufacturer's supervision. Overa
Instructions for the installer 2.3 Electrical connection Make sure that the voltage and capacity of the power supply cable conform to the data s
Instructions for the installer 26 2.4 Ventilation requirements The appliance may be installed only in rooms with permanent ventilation, as requi
Instructions for the installer 2.6 Gas connection Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe conf