Instructions for the Installer
12.1.1 Ovens with hob controls
On ovens with hob controls the power supply lead is not supplied. Use
a H05RR-F or H05RN-F rubber cable and when positioning it ensure that
it does not touch the metal parts of the appliance's external casing.
To access the terminal board, remove the appliance's back cover by
unscrewing the relative screws. If necessary, change the positions of the
jumpers on the terminal board as shown, then connect the wires, making
sure that the earth wire is at least 20 mm longer. Fix the power supply lead
to the appliance using the cable clamp provided.
Operation at 220-240V~: use a H05RR-
F / H05RN-F three-wire cable (cable of 3
x 4 mm
2
).
Operation at 380-415V2N~: use a
H05RR-F / H05RN-F four-wire cable
(cable of 4 x 2.5 mm
2
).
Operation at 380-415V3N~: use a
H05RR-F / H05RN-F five-wire cable
(cable of 5 x 1.5 mm
2
).
The earth wire (yellow-green) must be at
least 20 mm longer than the other wires
at the end for connection to the
appliance.