Smeg KSET96 Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
13GB
CLOSING ELEMENT
The space between the edge of the hood and
the rear wall can be closed by applying the
element 20 provided, using the screws supplied
for this purpose.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to the installer.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
Cut a hole ø 150 mm in the wall unit over the
hood.
Connect the hood body outlet to the top part of
the wall unit using a rigid or flexible pipe ø 150
mm, to be selected by the installer.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
When opening the sliding carriage for the first time after installing the hood, pull it out briskly
until it clicks.
20
9
125
150
ø150
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 43 44

Commentaires sur ces manuels

Pas de commentaire