Smeg FA166-5 Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
Instructions for the user
6
2. INSTALLATION
2.1 Electrical connection
Check that mains voltage and power cable ratings are as per the
indications provided on the label attached to the oven door frame.
This label must never be removed.
It is obligatory for the electrical system to be grounded according to the
methods required by safety rules.
If a plug and socket connection is being used make sure that the plug
and socket are compatible. Avoid use of adapters and shunts as these
could cause overheating and risk of burns.
If a fixed connection is being used fit power line with an omnipolar circuit
breaker with a contact opening gap equal to or greater than 3 mm in an
easily accessible position in proximity to the oven.
For operation on 230-250V
: use an
H05RR-F / H05RN-F / H05V2V2-F type
three-core cable (3 x 1.5 mm
2
).
The cable end to be connected to the
appliance must be provided with an ground
wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 23 24

Commentaires sur ces manuels

Pas de commentaire