Smeg S45MX2 Manuel de service Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
GB-IE
Instructions for the Installer
31
12 INSTALLING THE APPLIANCE
12.1 Electrical connection
The nameplate with the technical data, serial number and mark is in a
visible position on the oven door frame.
The nameplate must never be removed.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a permanent connection is used, the appliance's power supply line must
be fitted with an omnipolar breaking device with contact gap of at least 3
mm, located in an easily accessible position close to the appliance itself.
If a socket and plug connection is used, check that they are of the same
type. Do not use reducers, adapters or junctions since they may cause
overheating or burns.
12.2 Positioning the oven
The appliance is designed for building-in to cabinets made from any heat-
resistant material. Comply with the dimensions shown in following pictures.
When installing in tall units bear in mind that the top/rear of the unit must
have an opening 100 mm deep.
Screw the 4 screws into the inside of the frame.
Vue de la page 29
1 2 ... 25 26 27 28 29 30

Commentaires sur ces manuels

Pas de commentaire