Instructions for the User
11.6.3 Setting the cleaning cycle
Use PT2 to select one of the two pyrolysis functions ( and ) with the
oven in ON status (see point 7.4, Function Selection).
To start the cleaning (Pyrolysis) cycle, first press knob PT1 twice to set its
duration ( ).
Turn knob PT1 to the right or left to increase or decrease the cycle
duration between a minimum of 1h 30m and a maximum of 3h 00m.
(Except for the function where the cycle duration is fixed at 1h 30m).
The message PYro will appear on DSPL 3 to indicate that cleaning is in
progress. The temperature symbol « » will come on and the degree sign
«°» will flash to indicate that the internal pyrolysis temperature has not yet
been reached. When the preset temperature is reached the degree
symbol «°» will remain constantly on.
About 2 minutes after the cleaning (Pyrolysis) cycle starts an interlock
device which prevents opening of the door will be tripped.
The symbol illuminates on dps3 to indicate that this interlock device has
been activated.
To select a cleaning cycle with delayed start, after setting the duration
press PT1 once. The symbol and the current time will appear on the
display.
Turning PT1 to the right increases the time, allowing the cleaning start
time required to be set.
A few seconds after the required duration is set, the and symbols
will stop flashing, and the oven will start to wait for the starting time set.
It is not possible to select any functions once the door interlock has been
activated. Wait for the symbol to go out.