Instructions for the installer
The connection to the mains shall be done conforming to the regulations
in force. Check that the power line is adequately grounded. Do not use
reducers, adapters or shunts. On the power line, install an omnipolar cut-
off device with contact cut-off distance greater than or equal to 3 mm,
located in an easily accessible position near the unit.
The connection terminals are
located at the rear of the
appliance. For electrical
connections see following
diagram. To access, remove
the rear cover.
For operation on 380-415V3N
: use
an H05RR-F-type five-core cable (5 x
1.5 mm
2
).
For operation on 380-415V2N
: use
an H05RR-F-type four-core cable (4 x
2.5 mm
2
).
For operation on 220-240V
: use an
H05RR-F-type three-core cable (3 x 4
mm
2
).
The cable end to be connected to the
appliance must be provided with an
ground wire (yellow-
g
reen) at least 20
mm longer.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.