Instructions for the installer
30
4.1 Connection to LPG
Use a pressure regulator and make the connection to the tank
according to the provisions of standards regulations in force. Make sure
that feed pressure conforms to the levels shown in the table in
paragraph “5.3 Regulation for LPG”.
4.2 Ventilation of rooms
The hob may be installed only in rooms with permanent ventilation, as
required by standards regulations in force. The room in which the hob
is installed must have sufficient air flow to satisfy the requirements of
normal gas combustion and of necessary air exchange in the room.
The air intakes, protected by screens, must be appropriately sized
(regulations in force) and placed so as not to be blocked in any way.
The room where the oven is installed should be suitably ventilated to
avoid overheating or excess humidity produced by cooking, and in the
case of lengthy use a window should be opened or the speed of any
ventilators should be increased.
4.3 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration.
An efficient aspiration system requires careful planning by a specialist
capable of installing it, respecting the positions and distances
prescribed by standards. After installation, the installer must issue a
certificate of conformity.