Smeg CB66CES1 Manuel d'instructions Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
Instructions for the installer
7
2.2 Electrical connection
Check that the voltage and size of the power supply line are as specified on the nameplate inside the
storage compartment.
This nameplate must never be removed.
If a permanent connection to the electrical mains is used, the appliance's power supply line must be
fitted with an omnipolar breaking device with contact breaking gap of at least 3 mm located in an
easily accessible position close to the appliance itself.
Complete wiring up to power supply with an appropriately rated five-core plug (see data plate) or, in
case of operation from a 230-240V power supply, with a three-core plug. Make sure that plug and
wall socket are of the same type and are in conformity with regulations in force. Make sure that the
appliance is properly earthed. Before powering, check that the power line is properly earthed. Avoid
using adapters or shunters.
For operation on 400/415V3N
: use an H05RR-F / H05RN-F /
H05V2V2-F type five-core cable (5 x 2.5 mm
2
).
For operation on 400/415V2N
: use an H05RR-F / H05RN-F /
H05V2V2-F type five-core cable (cavo di 4 x 2.5 mm
2
).
For operation on 230/240V
: use an H05RR-F / H05RN-F /
H05V2V2-F (cavo di 3 x 4 mm
2
).
The cable end to be connected to the appliance must be provided with
an ground wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility for damage to persons or things caused b
y
non-observance of the above prescriptions or by interference with any part of the appliance.
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 11 12 13

Commentaires sur ces manuels

Pas de commentaire