Smeg SUK91MFX5 Manuel de service Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
Instructions for the installer
11
3.4 Burner and nozzle characteristics table (Mod. 60 cm.)
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0 50 30 350 73 71
Semi rapid
1.75 65 33 450 127 125
Rapid
3.0 85 45 800 218 214
Triple crown
3.2 91 65 1500 233 229
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary
1.0 72 350
Semi rapid
1.75 97 450
Rapid
3.0 115 800
Triple crown
3.5 133 1500
3.5 Arrangement of the burners on the hob (Mod. 60 cm.)
BURNERS
1.
Auxiliary
2.
Semi rapid
3. Rapid
4. Triple crown