This appliance is a high efficiency, flueless catalytic flame effect gas fire. It provides radiant and convected warmth both efficient-
ly and safely utilising the latest type catalytic converter and burner technology. The appliance does not require a flue system of
any type as the catalytic converter cleans the flue products to provide a complete combustion system, which is intrinsically safe.
It is designed to operate on Natural Gas or Propane (see data badge) and is factory set for operation on the gas type, and at the
pressure stated on the appliance data plate.
The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It must not be adjusted or put out of
operation. If replaced then manufacturer’s original parts must be used.
It is the LAW that all gas appliances and fittings are installed by a competent person and in accordance with the Gas Safety
(Installation and Use) Regulations 1998, the relevant British Standards for Installation, Codes of Practice and the Manufacturers'
Instructions.
At the time of writing, CORGI registered operatives are the only class of person considered as 'competent' by the HSE under
the above regulations.The installation shall also be carried out in accordance with the following:
Failure to comply with the above could lead to prosecution and deem the manufacturer’s warranty invalid.
This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space. The appli-
ance is designed to fit various types of situations as described in sections 3.0 and 4.0.The appliance must be installed in a cor-
rectly sized room (see section 3.1), and the correct purpose provided ventilation must be provided (see section 4.1).
It should be noted that heaters create warm air currents. These currents move heat to wall surfaces next to the heater. Installing
the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air (such as tobacco smoke, can-
dle smoke etc.) exist, may cause the walls to become discoloured.
This appliance is intended as a secondary source of heat only and should not be used in a room without some form of back-
ground heating present. If the appliance is used in a room as the sole source of heat, then condensation may occur on colder sur-
faces within the room.
On first light up of a new appliance, initial curing of high temperature paint and burning off of lubricants may occur for the first
few hours of operation. During this period some smoke may be emitted from the outlet grille, this should be no cause for con-
cern. Accordingly, the room should be well ventilated with all windows and doors open during this period. During this period the
appliance may cause smoke alarms to sound. If this happens, reset the alarms, but do not remove the batteries.
Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material.
.
1
Section Contents
Page No.
1.0 Important Notes 1
2.0 Appliance Data 2
3.0 Installation Requirements 2
3.1 Room Sizing 2
4.0 Site Requirements 2
4.1 Ventilation 3
5.0 Unpacking the Appliance 4
5.1 Component Checklist 4
6.0 Gas Supply Routes 4
7.0 Fixing the Appliance 4
7.1 Checking the Burner & Spark Gap 5
Section Contents
Page No.
8.0 Testing and Commisioning 5
8.1 Operating the Appliance 6
8.2 Setting pressure 6
8.3 Fitting the Decorative Frame 7
9.0 Briefing the customer 7
10.0 Servicing 7
10.1 Servicing the Burner Unit 8
10.2 Pilot Assembly 8
10.3 Catalysts 9
10.4 Testing for Firebox Leakage 9
11.0 Troubleshooting Guide 10
1.0 IMPORTANT NOTES
INSTALLATION INSTRUCTIONS
Manufacturers' Instructions.
The Building Regulations issued by the Department for Communities and Local Government, the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
Relevant British standards insofar as the relevant areas are not covered by these instructions.
For Republic of Ireland, reference should be made to the current edition of IS813 (the relevant standards governing installation).
©
2007 Smeg (UK) LTD
Vue de la page 2
1 2 3 4 5 6 7 8 ... 15 16

Commentaires sur ces manuels

Pas de commentaire