Smeg SE2951TC2 Manuel de service Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
57
Instructions for the installer
HOB TYPE
(CM)
POSSIBLE CONNECTION
TYPES
CABLE TYPE
(if not present)
60 - 70 -90
380 - 415 V 3N~ 5-pole 5 x 1.5 mm² H05V2V2-F
380 - 415 V 2N~ 4-pole 4 x 2.5 mm² H05V2V2-F
220 - 240 V 3~ 4-pole 4 x 2.5 mm² H05V2V2-F
60 - 70
220 - 240 V 1N~ 3-pole 3 x 4 mm² H05V2V2-F
90
220 - 240 V 1N~ 3-pole 3 x 6 mm² H05V2V2-F
Read the connection layout plate underneath the appliance or around the power cable with care.
Use H05V2V2-F cables resistant to at least 90 °C.
The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28

Commentaires sur ces manuels

Pas de commentaire