Smeg SCP490N-8 Manuel de service Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
Instructions for the installer
83
11.INSTALLING THE APPLIANCE
11.1 Electrical connection
The identification plate bearing the technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to earth in compliance with electrical system
safety regulations.
If the appliance is connected to the power supply network by means of a fixed
connection, install a multipolar cut-out device on the power supply line, in
accordance with the installation rules, located near the appliance and in an
easily reachable position.
If a plug and socket connection is being used, make sure that the plug and
socket are compatible. Avoid use of adapters and shunts as these could cause
overheating and a risk of burns.
Operation at 220-240 V~: use a H05V2V2-F type
three-core cable (3 x 1.5 mm
2
).
The end to be connected to the appliance must
have an earth wire (yellow-green) at least 20 mm longer than the others.
WARNING: The values indicated above refer to the cross-section of the
internal conductor.
Vue de la page 38
1 2 ... 34 35 36 37 38 39 40 41 42

Commentaires sur ces manuels

Pas de commentaire