33
FAULT DESCRIPTION
E7
Turbine flow-regulator malfunction
(for the relevant models only)
The appliance is not able to "measure" the amount of water loaded
accurately. Interrupt the program and switch off the dishwasher. Switch
the dishwasher back on, program it again and start the washing cycle. If
the problem persists, contact the after-sales service.
E8
Alternate washing system malfunction
Interrupt the program and switch off the dishwasher. Switch the
dishwasher back on, program it again and start the washing cycle. If the
problem persists, contact the after-sales service.
E9
Water intake system malfunction
Contact the after-sales service.
The
E1
,
E2
,
E3
,
E4
,
E8
,
E9
alarms provoke the “forcing” to end
cycle of the running program.
The
E5
,
E6
alarms interrupts the running program once the cause is
resolved, it will bring bach the execution of the program.
The alarm
E7
is visualized at the end of the cycle that comes,
however, brought to the end since the operation of the dishwasher is
not harmed.
To “reset” an alarm is necessary:
Open and close the door, or turn off and on the machine. At this
point is possible to program the dishwasher again.
If the fault persists, call the authorised Technical Service Centre.
TECHNICAL DATA
Width
597
÷
599 mm
Depth measured flush with the
outer edge of the control panel
Free standing: 600 mm
Semi-integrated: 570 mm
Height
Free standing from 850 mm to 870 mm
Semi-integrated from 820 mm to 870 mm
Capacity
14 Standard place settings
Water supply pressure
min. 0,05 - max. 0,9 MPa (min. 0.5 – max. 9 bar)
Electrical characteristics
See rating plate
User instructions