Smeg CW400RSD Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
7
KEYBOARD FUCNTIONALITY CW400RSD – CW400R
MAIN FUNCTIONS WITH MACHINE POWERED
ITEM Description Function
L1
Machine powered
led indicator
This led indicator turns on (green) when electrical current is present
L2
Tank emptying led
indicator
This led indicator (green) indicates that the machine is emptying the
Tank – the led flashes when the operation is in progress.
On/Off button
Pressing this button with led indicator 1 on activates the keyboard
and renders the machine operational.
The last program used (wash cycles) will be shown on the 3
displays when turned on.
Tank emptying
button
To empty the Tank first remove the Tank’s overflow, then press the
button for 3 seconds. This inhibits water from being loaded and,
after a Pressostat Tank-empty signal verifies that the Tank has
been emptied, will only allow a limited amount of boiler water to
circulate in order to facilitate the cleaning of the Tank.
At the end of the function the machine goes into a stand-by phase
which is indicated by the appearance of three dashes “---“ upon the
displays. To render the machine operational again it is therefore
necessary to insert the Tank’s overflow and to press the
button.
If the machine is equipped with the drain pump option, the drain
pump will also be activated.
Programs button
By repeatedly pressing this button the various wash cycles can be
viewed (brief 60”, medium 120”, long 180”, continuous)
OPTIONS button
The use of this button does the following, in sequence:
Enables the “crystal cycle” only with the medium cycle 120”
(“C” on the display”); Sets the T of the boiler from 85°C to
70°C
Enables regeneration (rig on the display) if decal is
installed. (if a program has not been set, it will not be
performed)
Tank led indicator
Indicates, when on, that the temperature shown during washing is
that of the Tank.
Salt led indicator
Indicates insufficient salt quantity (if prescribed in the function)
The led indicator turns on for the closing of a reed contact.
Boiler led indicator Boiler resistance in function symbol
Vue de la page 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 32 33

Commentaires sur ces manuels

Pas de commentaire