Connecting to the air gap (no waste disposal unit)

MAKE THE CONNECTION UPLINE FROM THE SIPHON OF THE
DRAIN LINE AND AT LEAST 400 mm (15-3/4”) ABOVE THE FLOOR
ON WHICH THE DISHWASHER WILL BE INSTALLED.
1.
Connect the dishwasher drain hose (ref. A fi g. 5-12) to the air gap (ref. B fi g.
5-12) using the wide spring clamp (ref. C fi g. 5-12); if necessary, cut the end
of the dishwasher drain hose (ref. D g. 5-12) (do not cut the corrugated
section). If the drain hose has been cut, use a 38 to 50 mm (1-1/2 to 2”)
screw clamp*.
2.
To connect the air gap (ref. B g. 5-12) to the “T” union (ref. E g. 5-12) of the
drain line, use a rubber union* (ref. F fi g. 5-12) with spring or screw clamps*
(ref. G fi g. 5-12).
* Available from any plumbing stockist
Fig. 5-12
B
C
A
F
G
G
D
E