INSTALLATION
5) ELECTRICAL CONNECTION
The electrical connection has to be done in
accordance with all electrical and installation
requirements of the regulation.
Before proceeding with the connection, please,
verify that:
- The power of the electrical system and the power
of the outlets is adequate to the maximum power
of the appliance (see the identification label in the
lower part of the body).
- The outelets and all the electrical system has an
efficient connection to the "earth" according with
the Regulation. We disclaim all responsabilities
for not observing such points.
- If the appliance is not equipped with an input
cable, connect to the clump with an adequate
section cable (see scheme paragraph 6) keeping
the "earth" conductor longer than "live" ones,
following the scheme of fig. 12 and 13.
When the connection to the input system has
been done through a outlet:
- Apply to the input cable "C", if unprovided, a
normalized plug adequate to the load indicated in
the identification label. Connect the cables
according to the scheme of fig.12 and fig. 13,
making sure to respect the undermentioned
respondences:
Letter L (Live) = cable brown colour;
Letter N (Neutral) = cable blue colour;
Symbol
(Earth) = cable green - yellow
colour.
- The input cable has to be located so that never
reach the over temperature of 75 K.
- Please do not use in the connection any
reduction, adaptation that may provoke a false
contact with following dangerous overheatings.
When the connection has been done directly to
the input system:
- Interpose between the appliance and the system
an onnipolar switch, adequate to the load of the
appliance, with a minimum nose between the
contacts of 3 mm.
- Keep in mind that the " earth " cable does not
have to be interrupted by the switch.
- In an alternative solution the electrical connection
can also be protected by a differential switch with
high sensitivity.
We recommend to fix the earth coloured cable to
an appropriate earth installation.
WARNINGS:
All our products are projected and built
according with the European Norms
EN 60 335-1 and EN 60 335-2-6 and relative
amendments.
The appliance has been produced according
with the European Directives:
- CEE 89/336 + 92/31 + 93/68 concerning the
compatibility electromagnetic.
- CEE 73/23 + 93/68 concerning the electrical
security.
FIG. 12
4 HEATING ELEMENTS
FIG. 13
1 or 2 HEATING ELEMENTS
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15