Instructions for the installer
11. INSTALLATION
11.1 Installing in kitchen units
Veneers, adhesives or plastic coatings on adjacent furniture should be temperature-resistant (no less
than 90°C). If they are not sufficiently temperature-resistant, they may warp over time.
The appliance must be installed by a qualified technician and according to the regulations in force.
Depending on the type of installation, this appliance belongs to class 2, subclass 1 (Fig. A - Fig. B) or to
class 1 (Fig. C).
It may be installed next to walls, one of which must be higher than the worktop, at a minimum distance of
50 mm from the side of the appliance, as shown in figures A and C relative to the installation classes.
Any wall units must be at a minimum distance of at least 750 mm above the appliance. This distance can
be reduced to 650 mm if a ventilation hood is installed.
Built-in appliance
(Class 2 subclass 1)
Built-in appliance
(Class 2 subclass 1)
Free-standing
appliance (Class 1)