Instructions for the installer
APPLIANCE
TYPE
(CM)
POSSIBLE CONNECTION
TYPES
CABLE TYPE
(if not present)
90
380 - 415 V 3N~ 5-pole 5 x 2.5 mm² H05V2V2-F
90
380 - 415 V 2N~ 4-pole 4 x 4 mm² H05V2V2-F
90
220 - 240 V 1N~ 3-pole 3 x 6 mm² H05V2V2-F
Use H05V2V2-F cables withstanding a temperature of at least 90°C.
The values indicated above refer to the cross-section of the internal conductor.
The tightening torque of the screws of the terminal supply wires must be 1.5 - 2 Nm.
The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).