Smeg TRU90BL Manuel d'instructions Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Installation
16
U.S. Installation only / 3-wire branch
circuit
Refer to figure, where local codes allow the
connection of the ground wire from the
oven to the power supply cable neutral
wire (white wire):
• The ground wire must be connected first;
• If local codes permit, connect the green
or yellow-green ground wire from the
range and the white wire from the range
to the power supply neutral wire (white
wire).
• Connect the red and black leads from
the range to the matching color wires in
the junction box using UL/CSA listed
wire connectors.
U.S. and Canada installation / 4-wire
branch circuit
• Separate the green or yellow-green
wires from the white wires that extend out
of the end of the appliance cable.
• The ground wire must be connected first.
• Connect the green or yellow-green
ground wire from the appliance to the
ground wire in the junction box (green
colored wire) using UL/CSA listed wire
connectors. Do not connect the
grounding wire to the neutral wire in the
junction box.
• Connect the red and black leads from
the appliance to the matching color
wires in the junction box using UL/CSA
listed wire connectors.
• Connect the white wire from the
appliance to the neutral white wire in the
junction box using a UL/CSA listed wire
connector.
A cable from power supply bw black wires
B junction box gw white-green or yellow-green wires
C cable from range rw red wires
D UL/CSA listed conduit connector ww white wires