Smeg PVA750D Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
Instructions for the Installer
31
5.5 Reassembling the hob skin
Reverse the procedure described in point “5.1 Removing the hob skin”.
When replacing the cover plates, check that the seals are fitted correctly.
7.1Fit the pan stands as described in point Fitting the pan stands.
5.6 Adjusting the minimum setting for natural ga
Reassemble the components on the burner and fit the
knobs onto the tap rods.
Light the burner and turn it to the minimum
setting.
Remove the knob again and adjust the regulator
screw inside or beside the tap rod (depending on the
model) until an even minimum flame is obtained.
Put the knob back in place and check the stability of
the burner flame (the flame must not go out when the
knob is turned quickly from the maximum to the
minimum setting).
5.7 Adjusting the minimum for bottled gas
To adjust the minimum level when using bottled gas, the adjuster screw inside or
beside the tap rod must be turned fully clockwise (depending on the models).
The diameters of the bypasses for each individual burner are stated in point “5.2
Adjusting for bottled gas".
After adjusting for use of a gas other than the gas used for testing the appliance,
replace the label on the casing with the label for the new gas. The label is supplied in
the bag with the LPG nozzles (G30 - G31).
5.8 Hob burner layout
Burner type
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
5.9 Greasing the gas taps
Over time, the gas taps may become stiff or jam. Clean their insides and change their
lubricating grease. This operation must be carried out by a skilled technician.
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 17 18

Commentaires sur ces manuels

Pas de commentaire