Cleaning and maintenance
74
Setting of programmed pyrolysis
It is possible to program the pyrolysis start
time.
7. After selecting the pyrolysis cycle
duration, press the temperature knob.
The display shows the current time and
the indicator light comes on.
8. Turn the temperature knob to set the time
at which you wish to terminate the
pyrolysis cycle.
9. After a few seconds, the and
indicator lights remain lit steadily and the
appliance waits for the set start time to
start the cleaning cycle.
4.11 Extraordinary maintenance
Replacing the internal light bulb
1. Completely remove all accessories from
inside the oven.
2. Remove the racks/trays support frames.
3. Remove the bulb cover using a tool (e.g.
a screwdriver).
4. Slide out and remove the lamp.
5. Replace the lamp with one of the same
type (40W).
6. Replace the cover correctly, so that the
moulded part of the glass is facing the
door.
7. Press the cover completely down so that
it attaches perfectly to the bulb support.
It is not possible to select any
function once the door locking
device has been activated.
Live parts
Danger of electrocution
• Disconnect the oven power supply.
Do not touch the halogen lamp
directly with your fingers, but wrap
it in an insulating material.
Vue de la page 33