Destination
Country
Cat
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
Pressure
(±1.5 mbar)
Low Burner
Pressure
(±0.75 mbar)
G20 G25
Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR
I
2H
20 - 2.60 2.35 1.50 1.35 13.7 13.6 4.3 4.4
DE, PL
I
2E
20 - 2.60 2.35 1.50 1.35 13.7 13.6 4.3 4.4
BE,FR
I
2E+ 20 25 2.6/2.4 2.35/2.15 1.5/1.4 1.35/1.25 13.7/16.9 13.6/17.0 4.3/5.6 4.4/5.5
NL
I
2L - 25 2.40 2.15 1.40 1.25 16.9 17 5.6 5.5
2.0 APPLIANCE DATA
Destination
Country
Cat
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
Pressure
(±1.5 mbar)
Low Burner
Pressure
(±0.75 mbar)
G20 G25
Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR
I
2H
20 - 2.0 1.8 1.0 0.9 18.7 18.6 4.1 4.0
DE, PL
I
2
E
20 - 2.0 1.8 1.0 0.9 18.7 18.6 4.1 4.0
B
E,FR
I
2
E+ 20 25 2.0/1.85 1.8/1.66 1.0/0.92 0.9/0.83 18.7/23.4 18.6/23.5 4.1/5.3 4.0/5.2
NL
I
2L - 25 1.85 1.66 0.92 0.83 23.4 23.5 5.3 5.2
P23 MODELS
Destination
Country
C
at
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
P
ressure
(±1.5 mbar)
Low Burner
P
ressure
(±0.75 mbar)
G20 G25
Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR
I
2H
20 - 2.0 1.8 1.3 1.17 18.7 18.6 7.4 7.3
DE, PL
I
2E
20 - 2.0 1.8 1.3 1.17 18.7 18.6 7.4 7.3
BE,FR
I
2E+ 20 25 2.0/1.85 1.8/1.66 1.3/1.2 1.17/1.08 18.7/23.4 18.6/23.5 7.4/9.3 7.3/9.2
NL
I
2L - 25 1.85 1.66 1.2 1.08 23.4 23.5 9.3 9.2
P23 MODELS L23 MODELS L30 MODELS
Flow Restrictor Orifice 1.03mm 1.03mm 1.30mm
Oxypilot (Sit/Bray) 9114 9114 9114
Gas Control BM733 BM733 BM733
Gas Inlet Various Various Various
Ignition Piezo Spark Piezo Spark Piezo Spark
Spark Gap 1.0mm) 4.0mm 4.0mm 4.0mm
3.0 INSTALLATION REQUIREMENTS
If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue must be
sealed off. It will be necessary to ventilate the old flue to prevent condensation and dampness forming, however any air vent used
to ventilate the old flue must not be sited within 500mm of this appliance. If the flue can be ventilated to the outside of the build-
ing then this is usually the best solution. If in doubt then advice should be sought from a local building control officer. The appliance
is designed to be wall mounted. If the appliance is to be mounted on a newly fabricated area of wall that also serves the purpose of
sealing off the old flue then it is very important that there are no holes, gaps or otherwise in this wall that will allow draughts from
the old flue to enter the room, especially directly behind the appliance. Such draughts could affect the performance of the ODS sys-
tem and result in nuisance cutting out, for example. If the gas supply pipe is to enter the appliance from the rear, i.e. emerge from
the wall behind the appliance, then any hole in the wall from which the pipe emerges must be tightly sealed.
In the absence of any local Codes and/or Regulations governing room sizing for type A1AS appliances then the information given
here must be followed.
P23 and L23 models : The room size should be a minimum of 23m
3
(e.g. 3.07m x 3.07m x 2.45m or 10'1" x 10'1" x 8').
L30 models : The room size should be a minimum of 30m
3
(e.g. 3.5m x 3.5m x 2.45m or 11'6" x 11'6" x 8').
This is to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces
but these spaces must not be separated by a door. Note : To calculate a room size in cubic metres (m
3
) divide the room volume
in cubic feet (ft
3
) by 35.3.
© 2008 Smeg S.p.A.
L23 MODELS
L30 MODELS
3.1 ROOM SIZING